Technical
Channels

Drug Delivery

QA/QC and Compliance

Pharmaceutical Processing and Packaging

Foxboro pH Sensor Improves Pharmaceutical Product, Process, Profits


Dated: 1/14/2008

About Raylo Chemical
Based in Edmonton, Alberta, Canada, Raylo Chemical is a member of the Degussa Fine Chemicals Division, the world market leader in specialty chemicals. Raylo Chemical has a 40-year history of custom manufacturing active pharmaceutical ingredients and advanced intermediates for innovative pharmaceutical and biopharmaceutical companies.

With extensive research, development, and production capabilities, Raylo Chemical works closely with customers to provide high-value intermediate-form drugs and final-form drugs in quantities ranging from one gram up to multi-ton batches.

Challenge
As a custom manufacturer, Raylo is faced with developing and scaling a wide range of chemistries and products and ultimately delivering these on a commercial basis.

“The compounds we produce are used in various human applications from cancer treatments to anti-virals. Processes have to be controlled tightly in order to insure quality and consistent high yields. While our products are generally high value, it is a competitive industry so delivering high yield to the customer is a must,” says Rob Pastushak, Senior Technical Supervisor of pharmaceutical manufacturing for Raylo.

“Batches typically range from 300 to 900 kilograms and even the slightest variation in our process has a significant impact on costs. If our process is off even slightly, the cost implications are significant. Over time, this could add up to substantial losses in production and profitability,” says Pastushak.

Another critical and ongoing challenge facing Raylo is demonstrating to its clients and the US Food and Drug Administration (FDA), that the company has complete control over its production process. The Raylo, Edmonton facility is Current Good Manufacturing Practices (CGMP) certified, which is a quality standard to assure that quality and repeatability are built into their production process.

All of the company’s production equipment must be tested and certified, which involves a strict qualification process for regulatory compliance and regular audits by the FDA. Raylo must document its process and ability to consistently deliver quality ingredients, in the high volumes required.

“The majority of our business involves exports to the US. If we don’t receive FDA approval, we will go out of business,” says Pastushak.

“We must clearly demonstrate that we control every aspect of our manufacturing process at all times, and that our instruments are properly calibrated on a regular basis. Given the value of the drugs we produce, our clients rightfully demand we work closely with them to develop cost-effective manufacturing processes that produce consistent yields.”

Problems With pH Measurement
To assure consistent product quality and maximize batch yields, Raylo launched an effort in 2003 to improve the efficiency of its manufacturing process. Pastushak focused on pH measurement.

“Measuring pH was a problem at that time because of the unreliability of our pH sensors. They simply could not hold up under aggressive chemicals that we use, such as hydrobromic acid. The organic solvent constituent caused the probe’s o-rings to degrade during the most critical point of the process. In many cases, three probes, at approximately $600 per probe, would fail during processing just one batch,” Pastushak says.

Once the O-ring degraded the pH probes no longer provided accurate readings, which presented another problem for Raylo. The process calls for two phases of crystallization, each of which requires pH measurement with tight tolerances of plus or minus 0.1 of the target value.

“Crystallization is critical and pH is king. When the chemical composition of a drug falls outside of the correct pH range, quality and yield suffer because maximum crystallization fails to occur,” says Pastushak.

Because of the unreliability of these devices, Raylo was forced to confirm pH measurements on a bench top meter in their lab. “When you process 3,000 to 5,000 liters and add 5 to 10 kilos of caustic solution at a time, it might take 20 to 40 lab tests to ensure the pH is right during pH adjustment,” says Pastushak. “Going to the lab so often to confirm pH just killed production efficiency, but it was a necessary evil to comply with the strict quality control standards that are essential to our business.”

Pastushak points out that given the competitive nature of the custom manufacturing business and the tight margins that exist in the industry, even a small 1 or 2 percent variance in yield can have a huge impact on the bottom line.

“A small 1 or 2 percent increase in the target commercial yield is translated as 100 percent profit. Likewise, a consistent loss of 1 or 2 percent of the commercial target yield translates as lost profit. You don’t stay in business long with this type of performance,” says Pastushak.

Solution
To resolve the pH measurement issue, Pastushak researched several probes and decided to test the Foxboro 871PH Series sensor, from the Measurements & Instruments Division of Invensys Process Systems. The 871 is a rebuildable pH probe that incorporates patented technology from the award-winning Foxboro DolpHin pH sensor line.

“We found many vendors that offered quality sensors, but Foxboro was the only one that could provide a robust design that could stand up to all the reagents and solvents in our solutions. The 871’s Ryton polymer plastic construction is compatible with all the materials in our process and is just what the doctor ordered for our demanding application,” says Pastushak.

The 871PH rebuildable sensor includes a robust and continuously reusable sensor body with a field replaceable measuring electrode, reference junction and electrolyte. When immersed into the process solution, the measuring electrode produces an electrical signal proportional to the hydrogen ion activity. The reference electrode provides a stable basis for comparison and completes the circuit. These two electrodes constitute an electrolytic cell with a millivolt output that is proportional to the pH of the solution.

The measuring electrode is the “business” area of the sensor and includes glass that comes in contact with the media being measured. The 871PH features a patented glass formulation that improves measurement stability, accuracy, and service life in high temperature applications, up to 250 degrees F. The glass also increases response speed up to five times compared with conventional sensors and allows longer duty cycles.

Proven In Process
To ensure the sensor met quality standards, Raylo put the Foxboro 871PH through extensive testing before integrating the unit into the manufacturing process.

Raylo utilizes the Foxboro 871PH probe in conjunction with two 7,600-liter reactor vessels stationed side-by-side with a shared condenser. One vessel serves as a reaction vessel and the other as a dissolute receiver, quench reactor or work-up reactor. When mixing organic reagents, acidic or basic by-products are often generated with potential impact to the product because of the changing pH.

To ensure that the product comes out of solution with the proper pH, Raylo typically dilutes the organic mixture with water. This mixture must then be measured for pH and adjusted until the right balance is achieved.

To adjust the pH, Raylo pump-circulates the solution through the bottom of each vessel to the top where the 871sensor measures pH in a slurry loop. Based on signals from the 871 sensor, a pre-made caustic or acid solution is added until the right level is achieved.

If the pH remains stable for two minutes, the pH test for any secondary crystallization level ensues. The 871 provides reactive, real-time pH measurements, which are key to reducing cycle time.

“We can now complete a pH adjustment in three hours rather than the 18 to 24 hours it previously took,” says Pastushak. “And we no longer have to take 40 samples to the lab to confirm measurement accuracy – we only take one, as a matter of quality assurance protocol. Previously, every time we grabbed a lab sample, we had to put the process on hold until we got the results back. This is significant when you consider not only the yield impact but the cost of a process hour.”

This reduction in the number of confirmation measurements also improved personnel safety. The fewer the confirmation measurements, the less times the technicians need to open the line to manually obtain samples. This fits in line with Raylo’s strong commitment to implementing the highest precautions with all of its safety controls.

Results
During an initial one-month test, Raylo discovered that the 871PH allowed them to control pH faster by adjusting to solution changes over a shorter period of time. “The results have been consistent from batch-to-batch,” says Pastushak.

“As soon as we add a solution to adjust pH, the probe responds immediately and provides the new pH reading. We’ve found it to be accurate to ±0.03 pH units, which are well within our target limits.”

The Foxboro 871PH sensor’s fast response, coupled with the sensor’s long reliable duty cycle and the elimination of 40 grab samples also allows Raylo to produce more batches in the same period of time. The faster, real-time readings have helped Raylo reduce manufacturing cycles by up to 20%, which increases capacity and competitiveness.

“Overall, yields have increased and cycle times have been shortened. When you add-in the increase in quality, the improved pH readings by one sensor can be worth hundreds of thousands of dollars per year,” Pastushak says.

According to Pastushak, the 871 PH sensor is also very durable. “The one we deployed two years ago looks like it did the day we bought it. All we do is clean it after each use. The Ryton bodies are holding up extremely well. They display no degradation, pitting or corrosion even though we run the gamut of pH ranges, solvents, and aggressive conditions,” says Pastushak.

Durability is critical in a chemical processing plant such as Raylo’s, where one delay can cause cascading impacts to the schedule. “When a day is lost in manufacturing, you lose it forever. A one-day delay can cause a backlog that snowballs from days to weeks to months for future batches,” says Pastushak.

During the past two years, Raylo has replaced three legacy probes within its manufacturing process and plans to replace three more. Raylo also has a second manufacturing facility with 15 probes that will eventually be swapped out as well.

“The bottom-line is that the 871PH has had a huge impact on the success of our business,” Pastushak says. “The role it plays is critical since pH failures can ruin an entire batch.”

But the benefits of Foxboro 871PH go far beyond improving Raylo’s bottom-line. “By enabling us to increase product quality and yield, the Foxboro 871PH sensor has allowed us to do our job better so we can contribute to improving the quality of life for countless people and that’s what we’re in business for,” says Pastushak.

  Related Industry Links
 
Pharmaceutical Society of Hong Kong (China)
Organization of Pharmaceutical Producers of India
 
 

Reed Business Information Asia | EM Asia | EM Asia (China) | Control Engineering Asia | Asia Food Journal
Drug Discovery & Development | Genomics & Proteomics | Pharmaceutical Processing | R&D | BioScience Technology

 
ABOUT PHARMA ASIA | FREE SUBSCRIPTION | CONTACT US
   
 
© 2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this web site is subject to its Terms and Conditions of Use. View our Privacy Policy.